The COMPAQ Elbow Terminal Protector (CRTP Series) is a high-performance insulating boot engineered to enhance the dielectric integrity of live terminations in cable entry boxes, RMUs, and compact transformer panels where space constraints increase the risk of phase-to-phase or phase-to-ground flashovers.

Designed for bushings with diameters from 46 mm to 56 mm, the CRTP fits seamlessly over C-type epoxy bushings and is compatible with HT cable sizes ranging from 25 sq.mm to 300 sq.mm. Manufactured from high-grade EPDM or silicone rubber, this moulded, reusable protector resists UV, tracking, pollution, and environmental stress, making it ideal for indoor and outdoor environments.

How Are We The Best

Product Benefits?

Quick and Easy Installation

One-piece, slip-on design allows rapid deployment on-site without tools or adhesives.

01

Wide Cable Compatibility

Supports cable cross-sections from 25 sq.mm to 300 sq.mm.

02

Prevents Flashover in Confined Spaces

Especially effective in humid, dusty, or rodent-prone environments.

03

Direct Voltage Testing Capability

Allows safe voltage detection without removing the protector.

04

Reusable & Cost-Effective

Long service life with the option to remove and reinstall.

05

Thermal Resilience

Continuous operation up to 90°C; withstands 130°C for 4 hours in overload conditions.

06

Fits Standard RMUs & Transformers

Specifically for applications with C-type bushings and limited clearance.

07
Specifications

Technical Specifications

Parameter Specification
Hardness 35 ± 10 Shore D (ASTM D2240)
Tensile Strength ≥10 N/mm² (ASTM D638)
Water Absorption ≤0.5% (ASTM D570)
CRTP-1224 (12 kV) 95 mm
CRTP-1224 (24 kV) 125 mm
Volume Resistivity ≥1 × 10¹³ Ohm·cm (ASTM D257)
Dielectric Constant ≤5 (ASTM D150)
Dielectric Strength ≥15 kV/mm (ASTM D149)
Ultimate Elongation ≥200% (ASTM D638)
Continuous Operating Temp −40 °C to +115 °C (IEC 216)
Emergency Overload Temp (4 hrs) +130 °C (–)
Impulse Withstand Test – 12 kV 75 kV
Impulse Withstand Test – 24 kV 125 kV
AC Withstand Test (1 min) – 12 kV 28 kV
AC Withstand Test (1 min) – 24 kV 50 kV
Choosing The Correct Kit

Applications

  • Ring Main Units (RMUs) with phase-to-phase clearance of 95 mm and phase-to-ground clearance of 60 mm
  • Air-insulated HT cable entry boxes and enclosures
  • Transformer bushings (46–56 mm diameter)
  • Metering panels, MS enclosures, and dry-type transformer terminations
  • Wildlife protection: prevents flashovers due to reptiles, birds, and rodents

Selection Criteria

To identify the correct kit configuration, kindly confirm the following project details:

Need Help?
Our experts are ready

Our experts are available for on-site support, remote guidance and tailored engineering.

Contact Us Contact Us
FAQS

Frequently Asked Questions (FAQ)

Yes. The material is UV- and weather-resistant, suitable for both indoor and outdoor installations.
It is designed primarily for bare or exposed bushing terminals. For screened connectors, COMPAQ offers other tailored boots.
Yes. The CRTP is designed to be reusable if removed carefully and undamaged.
Yes. It facilitates direct voltage testing without dismantling, ensuring safe operational diagnostics.